SCHNEIDER MCB 1 POLE
Contact Us
Specifications
Voltage: ~230240 V AC for single-phase circuits
Current Rating (Amp) : Available from a few amps (e.g., 4 A) up to 63 A or more depending on series.
Mounting Type: Standard DIN-rail mounting.
🔌 Schneider 1-Pole MCB Highlights
-
Schneider Electric Acti9 MCB 1P 6 A Curve C – Compact 6 A, type C breaker for small lighting circuits or low-load branches.
-
Schneider Electric Easy9 1P 16 A C‑Curve MCB – Very common choice (~16 A) for general outlet and lighting protection.
-
Schneider Electric Easy9 1P 16 A B‑Curve MCB – B-curve version, more sensitive to lower surge currents; useful for purely resistive loads.
-
Schneider Easy 9 Single Pole MCB – 32 A – Higher-current single-pole breaker (~32 A) for heavier circuits (e.g., water heaters, air handlers).
-
Schneider Resi9 MCB 1P 32 A Curve C – Another 32 A type C variant in the Resi9 range.
-
Schneider Electric Acti9 MCB 1P 63 A – Robust 63 A MCB for larger branch or sub-circuits.
-
Schneider Electric LS Switch 1P 4 A B‑Curve MCB – Lower-load breaker (~4 A) for small lighting or control circuits.
-
Schneider Electric Acti9 A9K MCB 1P 10 A – Mid-range 10 A type C breaker.
📊 Typical Specifications — Schneider MCB 1 Pole
These are general features common across Schneider single-pole MCBs:
-
Device Type: Miniature Circuit Breaker (MCB) — overload & short-circuit protection.
-
Poles: 1P — protects one live conductor.
-
Rated Voltage: ~230–240 V AC for single-phase circuits.
-
Rated Current Options: Available from a few amps (e.g., 4 A) up to 63 A or more depending on series.
-
Breaking Capacity: Typically 6 kA at 230 V AC (many Easy9/Acti9 models) — some higher-capacity ones offer 10 kA.
-
Trip Curves:
-
Type B: trips quickly at lower surges — good for lighting and resistive loads.
-
Type C: standard for general usage (lighting + outlets).
-
Type D: higher inrush tolerance (motors, high inductive loads).
-
-
Mounting: Standard DIN-rail mounting.
-
Standards: Complies with IEC 60898-1 and often IEC 60947-2 for overload/short-circuit protection.
-
IP Protection: Usually IP20 (indoor electrical panel use).
🧠 Quick Usage Notes
-
Rated Current: Choose closer to the actual circuit load — e.g., 6–10 A for lighting, 16–32 A for outlets or larger loads.
-
Trip Curve: Type C is the most versatile for mixed usage. Type B is more sensitive, and Type D tolerates higher inrush currents without nuisance trips.
-
Breaking Capacity: Higher kA ratings (e.g., 10 kA) give better protection in systems with higher fault currents.