SCHNEIDER MCB 2 POLE

联系我们

选择选项: TYPE, WATT
TYPE:
More
WATT:
More

数量


规格

电压: ~230 / 400 V AC

Mounting Type: Clip-on 35 mm DIN-rail for distribution boards


 

🔌 Recommended Schneider 2-Pole MCBs (Overview)

Schneider Electric Easy9 2P 16A C‑Curve MCB – ✔️ Great everyday choice for general circuits like lighting and small outlets. Moderate 16 A rating with C-curve for mixed loads.

Schneider A9F74232 iC60N 2P 32A C MCB – ✔️ Mid-range 32 A breaker with C-curve — good for larger branch circuits.

MCB 32A 2 Poles 10kA Schneider – ✔️ 32 A MCB with 10 kA breaking capacity for stronger fault current demands.

Schneider Electric A9N2P63D 63A D‑Curve MCB – ✔️ 63 A heavy circuit breaker with D-curve — useful where loads have high inrush (motors, compressors).

Schneider A9F74250 iC60N 2P 50A C MCB – ✔️ Mid-to-high current-rated MCB (50 A) with C-curve for bigger branch circuits.

Schneider Electric A9N2P02C 2A C MCB – Small 2 A MCB for control circuits or sensitive low-current protection.

Schneider Electric Acti9 IC60N 2P 4A B MCB – ✔️ 4 A B-curve variant — ideal where you want quicker trip on small faults (e.g., pure resistive circuits).

Schneider Electric Acti9 C120N 2P 100A MCB – 📌 High-capacity 100 A MCB for main feeds or large sub-circuits requiring substantial current protection.


📊 Typical Schneider 2-Pole MCB Specs

Most Schneider 2-pole MCBs — whether Easy9, Acti9, or Multi9 ranges — share common characteristics:

✔ Poles: 2P — protects two conductors at once (e.g., live + neutral)
✔ Trip technology: Thermal-magnetic (overload + short-circuit protection) 
✔ Trip curves available: B, C, D (choose based on load type) 
✔ Rated voltages: ~230 / 400 V AC (single-phase and two-phase)
✔ Breaking capacity: Common values around 6 kA to 10 kA at rated voltage; higher versions available for stronger fault environments
✔ Standards compliance: IEC/EN 60898-1 and IEC/EN 60947-2 for safety and reliability 
✔ Mounting: Clip-on 35 mm DIN-rail for distribution boards 


🧠 Quick Tips for Choosing the Right Model

  • Trip curve choice:

    • B-curve: Sensitive — good for lighting and resistive loads.

    • C-curve: Most general-purpose use (sockets, mixed loads).

    • D-curve: Better for inductive or high inrush loads (motors, compressors). 

  • Rated current: Pick an MCB rating close to the expected load — e.g., 16 A for lights, 32 A for heavier circuits.

  • Breaking capacity: Higher values (e.g., 10 kA) are safer where the incoming fault current in your panel is potentially high.

 